Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Year range
1.
Rev. Esc. Enferm. USP ; 52: e03410, 2018. tab
Article in English, Portuguese | LILACS, BDENF | ID: biblio-985029

ABSTRACT

ABSTRACT Objective: To examine the incidence of hemorrhagic complications in patients undergoing radial cardiac catheterization and using a hemostatic device for arterial compression. Method: A prospective cohort study conducted with patients undergoing elective cardiac catheterization in two hemodynamic laboratories in southern Brazil. The TR Band® radial compression device was used during 4 hours for hemostasis of the arterial puncture site. Hematomas and minor bleeding were the outcomes evaluated. Results: A total of 244 patients were evaluated. The mean age was 63.5±10.9 years, 61.9% were male, 73.8% had systemic arterial hypertension (SAH) and 42.8% were dyslipidemic. Type I hematoma occurred in 1.2% of patients and minor bleeding in 9% after removal of the device. There was no significant association between hematomas and bleeding, and patients who used oral anticoagulants (p=0.604) and prior use of antiplatelets (p=0.958). Conclusion: The use of the hemostatic device for radial artery compression was safe in clinical practice and there was a low incidence of hematomas and minor bleeding after radial coronary angiography.


RESUMEN Objetivo: Verificar la incidencia de complicaciones hemorrágicas en pacientes sometidos a cateterismo cardiaco radial y con el uso de pulsera hemostática para compresión arterial. Método: Estudio de cohorte prospectivo, conducido con pacientes sometidos a cateterismo cardiaco electivo, en dos laboratorios de hemodinámica en el sur de Brasil. Para la hemostasia del sitio de punción arterial, se utilizó la pulsera de compresión radial TR Band® por 4 horas. Los resultados evaluados fueron hematomas y sangrado menor. Resultados: Fueron evaluados 244 pacientes, con edad media de 63,5±10,9 años, el 61,9% del sexo masculino, el 73,8% con hipertensión arterial sistémica y el 42,8% dislipidémicos. Ocurrió el 1,2% de hematoma tipo I y el 9% de sangrado menor después de la retirada de la pulsera. No hubo asociación significativa entre hematomas y sangrados y los pacientes que hacían uso de anticoagulante oral (p=0,604) y uso previo de antiplaquetario (p=0,958). Conclusión: El uso de la pulsera hemostática para compresión de la arteria radial se mostró segura en la práctica clínica y con reducida incidencia de hematomas y sangrado menor luego de cinecoronariografía por vía radial.


RESUMO Objetivo: Verificar a incidência de complicações hemorrágicas em pacientes submetidos a cateterismo cardíaco radial e com uso de pulseira hemostática para compressão arterial. Método: Estudo de coorte prospectivo, conduzido com pacientes submetidos a cateterismo cardíaco eletivo, em dois laboratórios de hemodinâmica no sul do Brasil. Para a hemostasia do sítio de punção arterial, foi utilizada a pulseira de compressão radial TR Band® por 4 horas. Os desfechos avaliados foram hematomas e sangramento menor. Resultados: Foram avaliados 244 pacientes, com idade média de 63,5±10,9 anos, 61,9% do sexo masculino, 73,8% com hipertensão arterial sistêmica e 42,8% dislipidêmicos. Ocorreram 1,2% de hematoma tipo I e 9% de sangramento menor depois da retirada da pulseira. Não houve associação significativa entre hematomas e sangramentos e os pacientes que faziam uso de anticoagulante oral (p=0,604) e uso prévio de antiplaquetário (p=0,958). Conclusão: O uso da pulseira hemostática para compressão da artéria radial mostrou-se segura na prática clínica e com reduzida incidência de hematomas e sangramento menor após cinecoronariografia por via radial.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Cardiac Catheterization , Radial Artery , Hemodynamics , Prospective Studies , Cohort Studies , Cardiovascular Nursing